Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
Imaging Sci Dent ; 54(1): 63-69, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38571779

RESUMO

Purpose: The objective of this study was to determine the minimum number of teeth in the anterior dental arch that would yield accurate results for individual identification in forensic contexts. Materials and Methods: The study involved the analysis of 28 sets of 3-dimensional (3D) point cloud data, focused on the labial surface of the anterior teeth. These datasets were superimposed within each group in both genuine and imposter pairs. Group A incorporated data from the right to the left central incisor, group B from the right to the left lateral incisor, and group C from the right to the left canine. A comprehensive analysis was conducted, including the evaluation of root mean square error (RMSE) values and the distances resulting from the superimposition of dental arch segments. All analyses were conducted using CloudCompare version 2.12.4 (Telecom ParisTech and R&D, Kyiv, Ukraine). Results: The distances between genuine pairs in groups A, B, and C displayed an average range of 0.153 to 0.184 mm. In contrast, distances for imposter pairs ranged from 0.338 to 0.522 mm. RMSE values for genuine pairs showed an average range of 0.166 to 0.177, whereas those for imposter pairs ranged from 0.424 to 0.638. A statistically significant difference was observed between the distances of genuine and imposter pairs (P<0.05). Conclusion: The exceptional performance observed for the labial surfaces of anterior teeth underscores their potential as a dependable criterion for accurate 3D dental identification. This was achieved by assessing a minimum of 4 teeth.

2.
J Indian Soc Pedod Prev Dent ; 42(1): 64-70, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38616429

RESUMO

AIM: This study aimed to validate the accuracy of dental age (DA) based on the dental development of permanent teeth in children with special needs using Demirjian, Willems, and London Atlas methods and to correlate the dental and chronological age (CA) of children with special needs in Malaysia. MATERIALS AND METHODS: The panoramic radiographic images belonging to children with special needs from the two teaching dental hospitals in Malaysia aged between 5 and 16 years were included in the study. The evaluation was performed by two observers using three methods (London Atlas, Demirjian, and Willems methods) to estimate the accurate DA. The outcome was determined by comparing the mean of the DA and CA. RESULTS: A total of 52 panoramic radiographs were available for the analysis. The London Atlas and Demirjian methods overestimated the DA with a mean of 0.05 and 0.20 years, respectively, while the Willems method underestimated by 0.19 years. The London Atlas method was highly precise and accurate, while Demirjian and Willems methods were the least precise and accurate. CONCLUSION: The London Atlas method of DA estimation is highly accurate and valid for children with special needs in the Malaysian population, followed by the Willems and Demirjian methods.


Assuntos
Determinação da Idade pelos Dentes , Crianças com Deficiência , Criança , Humanos , Pré-Escolar , Adolescente , Radiografia Panorâmica
3.
Nutr J ; 23(1): 11, 2024 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-38233923

RESUMO

Excessive sugar consumption is well documented as a common risk factor for many Non-Communicable Diseases (NCDs). Thus, an adequate intervention description is important to minimise research waste and improve research usability and reproducibility. A systematic review was conducted to identify components in published evidence interventions pertaining to the health promotions on reducing sugar intake among adults. The review was conducted in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement and used the Mixed Methods Appraisal Tool (MMAT) for quality appraisal. The period for the selected study was from 2000 to 2022, and articles were retrieved from Web of Science (WOS), Medline, Scopus, and PubMed. The target population was adults aged 18 years old and above who underwent intervention to assess the changes in their sugar intake. Data sources and all human epidemiologic studies were included. Out of the 9,333 papers identified, 25 were included. The overall quality of evidence of the studies was considered moderate. Apart from the characteristics of the reviewed studies, components of interventions are including the basis of theoretical or model for the intervention, which majority use Social Cognitive Theory, followed by PRECEDE-PROCEED model, socio-ecological and process-improvement theories and Transtheoretical Model; providers, who are commercial provider, qualified nutritionist, professor of nutrigenomics and nutrigenetics, doctor, dietitian nutritionist, lifestyle coaches, and junior public health nurses; duration of the intervention and follow-up time, varies from as short as one month to as long as 24 months; material provided either softcopy or hardcopy; tailoring approach, based on the individual goals, the process of change, genotype analysis, beliefs, barriers, and sociocultural norms; delivery mechanism either face-to-face or technology-mediated; and tools to measure the sugar consumption outcome mostly used Food Frequency Questionnaire (FFQ), besides 24-h dietary recalls, and food diaries. There are various components in downstream health promotion to reduce sugar intake among adults that can be adapted according to the local health promotion and intervention context. More well-designed interventions using integration components are encouraged in further studies.


Assuntos
Dieta , Promoção da Saúde , Adulto , Humanos , Açúcares da Dieta , Reprodutibilidade dos Testes
4.
Leg Med (Tokyo) ; 67: 102399, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38219704

RESUMO

The field of bitemark analysis involves examining physical alterations in a medium resulting from contact with teeth and other oral structures. Various techniques, such as 2D and 3D imaging, have been developed in recent decades to ensure precise analysis of bitemarks. This study assessed the precision of using a smartphone camera to generate 3D models of bitemark patterns. A 3D model of the bite mark pattern was created using 3Shape TRIOSTM and a smartphone camera combined with monoscopic photogrammetry. The mesiodistal dimensions of the anterior teeth were measured using Rapidform Explorer and OrtogOnBlender, and the collected data were analyzed using IBM® SPSS® Statistics version 23.0. The mean mesiodistal dimension of the anterior teeth, as measured on the 3D model from 3Shape TRIOSTM and smartphone cameras, was found to be 6.95 ± 0.7667 mm and 6.94 ± 0.7639 mm, respectively. Statistical analysis revealed no significant difference between the two measurement methods, p > 0.05. The outcomes derived from this study unequivocally illustrate that a smartphone camera possessing the specific parameters detailed in this study can create a 3D representation of bite patterns with an accuracy level on par with the outputs of a 3D intraoral camera. These findings underscore the promising trajectory of merging smartphone cameras and monoscopic photogrammetry techniques, positioning them as a budget-friendly avenue for 3D bitemark analysis. Notably, the monoscopic photogrammetry methodology assumes substantial significance within forensic odontology due to its capacity for precise 3D reconstructions and the preservation of critical measurement data.


Assuntos
Mordeduras Humanas , Dente , Humanos , Smartphone , Estudos de Viabilidade , Odontologia Legal/métodos , Imageamento Tridimensional
5.
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1431044

RESUMO

Abstract Bitemark analysis is a challenging procedure in the field of criminal case investigation. The unique characteristics of dentition are used to find the best match between the existing patterned injury and the suspected perpetrator in bitemark identification. Bitemark analysis accuracy can be influenced by various factors, including biting pressure, tooth morphology, skin elasticity, dental cast duplication, timing, and image quality. This review article discusses the potential of a smartphone camera as an alternative method for 3D bitemark analysis. Bitemark evidence on human skin and food should be immediately recorded or duplicated to retrieve long-lasting proof, allowing for a sufficient examination period. Various studies utilizing two-dimensional (2D) and three-dimensional (3D) technologies have been developed to obtain an adequate bitemark analysis. 3D imaging technology provides accurate and precise analysis. However, the currently available method using an intraoral scanner (IOS) requires high-cost specialized equipment and a well-trained operator. The numerous advantages of monoscopic photogrammetry may lead to a novel method of 3D bitemark analysis in forensic odontology. Smartphone cameras and monoscopic photogrammetry methodology could lead to a novel method of 3D bitemark analysis with an efficient cost and readily available equipment.


Assuntos
Mordeduras Humanas/diagnóstico por imagem , Fotogrametria/instrumentação , Smartphone , Odontologia Legal , Reconhecimento de Identidade , Antropologia Forense , Imageamento Tridimensional/métodos , Odontometria
6.
BMC Med Ethics ; 23(1): 117, 2022 11 21.
Artigo em Inglês | MEDLINE | ID: mdl-36414962

RESUMO

BACKGROUND: The research shows a growing trend in using an electronic platform to supplement or replace traditional paper-based informed consent processes. Instead of the traditionally written informed consent document, electronic informed consent (eConsent) may be used to assess the research subject's comprehension of the information presented. By doing so, respect for persons as one of the research ethical principles can be upheld. Furthermore, these electronic methods may reduce potential airborne infection exposures, particularly during the pandemic, thereby adhering to the beneficence and nonmaleficence principle. This scoping review aims to identify the ethics related criteria that have been included in electronic informed consent processes and to synthesize and map these criteria to research ethics principles, in order to identify the gaps, if any, in current electronic informed consent processes. METHODS: The search was performed based on internet search and three main databases: PubMed, SCOPUS and EBSCO. PRISMA Extension for Scoping Reviews (PRISMA-ScR): Checklist and Explanation guideline was used to report this work. RESULTS: Of 34 studies that met the inclusion criteria, 242 essential original constructs were collated, and 7 concepts were derived. Digital content showed the highest percentage of collated original constructs (27%, n = 65) followed by accessibility (24%, n = 56), comprehension engagement (18%, n = 43), autonomy (14%, n = 34), confidentiality (11%, n = 25), language (5%, n = 13), and parental consent (1%, n = 2). Twenty-five new items were synthesized for eConsent criteria which may provide guidance for ethical review of research involving eConsent. CONCLUSION: The current study adds significant value to the corpus of knowledge in research ethics by providing ethical criteria on electronic informed consent based on evidence-based data. The new synthesized items in the criteria can be readily used as an initial guide by the IRB/REC members during a review process on electronic informed consent and useful to the future preparation of a checklist.


Assuntos
Ética em Pesquisa , Consentimento Livre e Esclarecido , Humanos , Beneficência , Termos de Consentimento , Eletrônica
7.
Artigo em Inglês | MEDLINE | ID: mdl-36232177

RESUMO

A systematic review was performed to identify all the related publications describing PCSK9 and atherogenesis biomarkers attenuation associated with a natural product and plant bioactive compounds in in vitro studies. This review emphasized the imprecision and quality of the included research rather than the detailed reporting of the results. Literature searches were conducted in Scopus, PubMed, and Science Direct from 2003 until 2021, following the Cochrane handbook. The screening of titles, abstracts, and full papers was performed by two independent reviewers, followed by data extraction and validity. Study quality and validity were assessed using the Imprecision Tool, Model, and Marker Validity Assessment that has been developed for basic science studies. A total of 403 articles were identified and 31 of those that met the inclusion criteria were selected. 13 different atherogenesis biomarkers in relation to PCSK9 were found, and the most studied biomarkers are LDLR, SREBP, and HNF1α. In terms of quality, our review suggests that the basic science study in investigating atherogenesis biomarkers is deficient in terms of imprecision and validity.


Assuntos
Aterosclerose , Produtos Biológicos , Biomarcadores , Humanos , Compostos Fitoquímicos , Pró-Proteína Convertase 9 , Proteína de Ligação a Elemento Regulador de Esterol 1
8.
Clin Exp Dent Res ; 8(5): 1213-1217, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35837766

RESUMO

OBJECTIVES: The aim of this study was twofold: (i) to measure the bite force of healthy adults and patients with tooth pain and (ii) to evaluate the influence of bite force and age on tooth pain and both genders. It is hypothesized that patients with tooth pain would have lesser bite forces as compared to healthy individuals. MATERIAL AND METHODS: Two groups of participants were, the first group comprised 18 healthy adults (9 males, 9 females), while the second group comprised 18 patients with tooth pain (9 males, 9 females), recruited from the Faculty of Dentistry, Universiti Teknologi MARA. Their maximum bite forces were recorded using the Prescale system that consists of pressure-sensitive films and a precalibrated scanning device. Logistic regression models were used using bite force and age on dichotomous responses of tooth pain status and gender. RESULTS: The mean bite force of patients with tooth pain was 684.77 ± 501.13 N, which was lesser than 798.33 ± 492.16 N of the healthy adults. The reduced gender logistic regression model on gender with age was found to be statistically significant (p ≤ .05). CONCLUSIONS: Even though the mean bite force was smaller in the group with dental pain, this difference was not statistically significant.


Assuntos
Força de Mordida , Dente , Adulto , Feminino , Nível de Saúde , Humanos , Masculino , Dor/etiologia , Dente/fisiologia
9.
BMC Med Imaging ; 22(1): 66, 2022 04 08.
Artigo em Inglês | MEDLINE | ID: mdl-35395737

RESUMO

BACKGROUND: This study aims to propose the combinations of image processing and machine learning model to segment the maturity development of the mandibular premolars using a Keras-based deep learning convolutional neural networks (DCNN) model. METHODS: A dataset consisting of 240 images (20 images per stage per sex) of retrospect digital dental panoramic imaging of patients between 5 and 14 years of age was retrieved. In image preprocessing, abounding box with a dimension of 250 × 250 pixels was assigned to the left mandibular first (P1) and second (P2) permanent premolars. The implementation of dynamic programming of active contour (DP-AC) and convolutions neural network on images that require the procedure of image filtration using Python TensorFlow and Keras libraries were performed in image segmentation and classification, respectively. RESULTS: Image segmentation using the DP-AC algorithm enhanced the visibility of the image features in the region of interest while suppressing the image's background noise. The proposed model has an accuracy of 97.74%, 96.63% and 78.13% on the training, validation, and testing set, respectively. In addition, moderate agreement (Kappa value = 0.58) between human observer and computer were identified. Nonetheless, a robust DCNN model was achieved as there is no sign of the model's over-or under-fitting upon the learning process. CONCLUSIONS: The application of digital imaging and deep learning techniques used by the DP-AC and convolutions neural network algorithms to segment and identify premolars provides promising results for semi-automated forensic dental staging in the future.


Assuntos
Dente Pré-Molar , Aprendizado Profundo , Algoritmos , Dente Pré-Molar/crescimento & desenvolvimento , Humanos , Processamento de Imagem Assistida por Computador/métodos , Redes Neurais de Computação
10.
J Contemp Dent Pract ; 22(11): 1237-1242, 2021 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-35343447

RESUMO

AIM AND OBJECTIVE: The aim of this paper is to ascertain the quantitative measurements of alveolar bone thickness at all maxillary anterior teeth and qualitatively demonstrate the relationship between tooth angulation (TA) and alveolar bone thickness. MATERIALS AND METHODS: Cone-beam computed tomography (CBCT) images of 189 maxillary anterior teeth were collected. Sagittal view was selected to perform the measurement on alveolar bone wall at crestal, midlevel, and palatal. TA was measured along to the tooth long axis (TLA) related to the alveolar bone housing. Spearman's correlation coefficients were conducted to test the correlation between the variables. RESULTS: The facial alveolar bone (FAB) is predominantly thin (<1 mm) at the crestal and midroot region. A significant difference was recorded in the median thickness of FAB at the midroot and apical area (p = 0.001, p = 0.021). The FAB thickness was not gradual with midroot being thinner than crestal. For the palatal alveolar bone (PAB), the thickness was increased continuously toward the apex. At all apical levels of inspected teeth, a significant negative correlation existed between TA and FAB. A positive correlation of TA was only significant at the facial crest of lateral incisor (r = 0.308). However, the canines did not correlate with the FAB, but correlated with the PAB at the apical level (r = 0.478). CONCLUSION: The FAB wall crest of maxillary anterior teeth was generally thin and not gradual with the lateral incisor being the thinnest. A significant correlation of TA existed based on different types of maxillary anterior teeth and alveolar bone level. The maxillary anterior teeth with increased buccolingual angulation were correlated with thicker bone at the apical level. CLINICAL SIGNIFICANCE: The quantitative assessment of FAB and TA in degree may serve as an anatomical index for ideal implant position.


Assuntos
Processo Alveolar , Maxila , Processo Alveolar/diagnóstico por imagem , Tomografia Computadorizada de Feixe Cônico/métodos , Incisivo/diagnóstico por imagem , Maxila/diagnóstico por imagem , Palato
11.
Clin Oral Investig ; 25(3): 923-932, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32535703

RESUMO

OBJECTIVES: The aim of this study was to evaluate the accuracy of cone beam computed tomography (CBCT), periapical radiograph, and intrasurgical linear measurements in the assessment of molars with furcation defects. MATERIALS AND METHODS: This parallel, single-blinded, randomised controlled trial (RCT) consisted of 22 periodontitis patients who had molar with advanced furcation involvement (FI). All patients followed the same inclusion criteria and were treated following the same protocol, except for radiographic evaluation (CBCT vs. periapical). This study proposed and evaluated five parameters that represent the extent and severity of furcation defects in molars teeth, including CEJ-BD (clinical attachment loss), BL-H (depth), BL-V (height), RT (root trunk), and FW (width). RESULTS: There were no statistically significant differences between CBCT and intrasurgical linear measurements for any clinical parameter (p > 0.05). However, there were statistically significant differences in BL-V measurements (p < 0.05) between periapical and intrasurgical measurements in maxillary molars. Meanwhile, the sensitivity were 62.8% and 56.9% for CBCT and periapical, respectively. CONCLUSIONS: Overall, when compared to the intrasurgical measurements, CBCT provided better diagnostic, sensitivity, and quantitative information on CAL, height, depth, and width of the furcation defects than periapical radiograph. CLINICAL RELEVANCE: An accurate presurgical furcation diagnostic can guide the clinicians from the stage of diagnosis to definitive management so that unnecessary periodontal surgical interventions can be prevented.


Assuntos
Defeitos da Furca , Procedimentos Cirúrgicos Bucais , Periodontite , Tomografia Computadorizada de Feixe Cônico , Defeitos da Furca/diagnóstico por imagem , Defeitos da Furca/cirurgia , Humanos , Dente Molar/diagnóstico por imagem , Dente Molar/cirurgia
12.
Saudi Dent J ; 32(8): 396-402, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33304083

RESUMO

OBJECTIVE: Knowledge and evaluation of the blood supply within the maxillary sinus before sinus augmentation are vital to avoid surgical complications. The lateral maxilla is supplied by branches of the posterior superior alveolar artery and infraorbital artery forming intraosseous anastomoses (IA) within the bony lateral antral wall. This study was undertaken to (i) measure mean diameter of IA and its distance from the alveolar ridge within dentate and posteriorly edentulous subjects and, (ii) qualitatively display the relationship of IA throughout its course within the lateral maxillary sinus in cone beam computed tomography (CBCT). METHOD: Maxillary CBCT images of two-hundred-and-fifty-seven consecutive patients (163 men, 94 women, mean age 42 years) were analyzed. Samples were later divided into dentate (n = 142) and posteriorly edentulous (n = 115) jaws. Using both alveolar ridge and tooth location as reference points, the distance and diameter of IA were assessed. RESULT: The IA was seen in 63.7% of all sinuses with 68.2% in dentate and 62.4% in edentulous. Mean distance and diameter of IA across the posterior tooth locations were 17.9 ± 3.0 mm and 1.4 ± 0.5 mm (dentate) and 15.1 ± 3.0 mm and 1.0 ± 0.5 mm (posteriorly edentulous), respectively. In each sample, there were no significant differences in distance-alveolar ridge and no significant correlations in diameter-tooth location. A statistically significant Pearson coefficient correlation between diameter and distance in dentate state was observed (r = -0.6). CONCLUSION: This study reveals that dentate maxillary jaws present larger diameters as compared to posteriorly edentulous jaws, although the IA course remains the same. As these canal structures contain neurovascular bundles with diameters that may be large enough to cause clinically substantial complications, a thorough pre-surgical planning is therefore highly advisable.

13.
J. oral res. (Impresa) ; 8(6): 527-539, dic. 28, 2019. ilus, tab, graf
Artigo em Inglês | LILACS | ID: biblio-1224625

RESUMO

Objective: This study aims to assess the accuracy of the linear measurements of intrabony and/or furcation defect quantified by cone beam computed tomography (CBCT). Material and Methods: A systematic search of the literature was conducted by two authors independently from the PubMed, Scopus, and EBSCO for full articles published in journals between January 2003 and March 2017. Eligible studies were assessed for quality and heterogeneity using the QUADAS-2 tool. A meta-analysis was performed to identify the accuracy of CBCT in the measurement of intrabony defects. The effect size was estimated and reported as the standardised mean difference (SMD). Results: A total of 105 titles and abstracts were screened. Of those, 11 articles met the inclusion criteria for the systematic review while only four were selected for meta-analysis. The overall effects of standardized mean difference and 95% CI was -0.03 [95% CI -0.67 to 0.60] with a x2 statistic of 0.49 with 3 degrees of freedom (p>0.05), I2= 0.01%. Conclusion: CBCT is highly accurate and reproducible regarding linear measurements for assessing intrabony defects with a weighted standardized mean difference of 0.03 mm. More randomised controlled trials are required to assess the accuracy of CBCT in assessing patients with periodontal defects.


Objetivo: Este estudio tiene como objetivo evaluar la precisión de las mediciones lineales de defectos intraóseos y/o de furcación cuantificados por tomografía computarizada de haz cónico (CBCT). Material y Métodos: Dos autores, independientemente realizaron una búsqueda sistemática de la literatura en PubMed, Scopus y EBSCO, para obtener artículos completos publicados en revistas entre Enero de 2003 y Marzo de 2017. Los estudios elegibles se evaluaron para determinar la calidad y la heterogeneidad utilizando la herramienta QUADAS-2. Se realizó un metanálisis para identificar la precisión de CBCT en la medición de defectos intraóseos. El tamaño del efecto se estimó y se informó como la diferencia de medias estandarizada (DME). Resultados: Se seleccionaron un total de 105 títulos y resúmenes. De ellos, 11 artículos cumplieron con los criterios de inclusión para la revisión sistemática, mientras que solo cuatro fueron seleccionados para el metanálisis. Los efectos generales de la diferencia de medias estandarizada y el IC del 95% fueron -0.03 [IC del 95%: -0.67 a 0.60] con una estadística X2 de 0.49 con 3 grados de libertad (p>0.05), I2= 0.01%. Conclusión: CBCT es altamente preciso y reproducible con respecto a mediciones lineales para evaluar defectos intraóseos con una diferencia de medias estandarizada ponderada de 0.03 mm. Se requieren más ensayos controlados aleatorios para evaluar la precisión de CBCT en la evaluación de pacientes con defectos periodontales.


Assuntos
Humanos , Doenças Periodontais/diagnóstico por imagem , Periodontite/diagnóstico por imagem , Tomografia Computadorizada de Feixe Cônico , Bases de Dados Bibliográficas , Defeitos da Furca
14.
Imaging Sci Dent ; 47(4): 233-239, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29279822

RESUMO

PURPOSE: This study was performed to quantify the repeat rate of imaging acquisitions based on different clinical examinations, and to assess the prevalence of error types in intraoral bitewing and periapical imaging using a digital complementary metal-oxide-semiconductor (CMOS) intraoral sensor. MATERIALS AND METHODS: A total of 8,030 intraoral images were retrospectively collected from 3 groups of undergraduate clinical dental students. The type of examination, stage of the procedure, and reasons for repetition were analysed and recorded. The repeat rate was calculated as the total number of repeated images divided by the total number of examinations. The weighted Cohen's kappa for inter- and intra-observer agreement was used after calibration and prior to image analysis. RESULTS: The overall repeat rate on intraoral periapical images was 34.4%. A total of 1,978 repeated periapical images were from endodontic assessment, which included working length estimation (WLE), trial gutta-percha (tGP), obturation, and removal of gutta-percha (rGP). In the endodontic imaging, the highest repeat rate was from WLE (51.9%) followed by tGP (48.5%), obturation (42.2%), and rGP (35.6%). In bitewing images, the repeat rate was 15.1% and poor angulation was identified as the most common cause of error. A substantial level of intra- and interobserver agreement was achieved. CONCLUSION: The repeat rates in this study were relatively high, especially for certain clinical procedures, warranting training in optimization techniques and radiation protection. Repeat analysis should be performed from time to time to enhance quality assurance and hence deliver high-quality health services to patients.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...